Hospitals, Universities and Medical Centres Chiropractors Dentistry Veterinary

Up & coming Exhibitions

X-Ray Table: Vet-Tech Classic

A.Somerville Limited is proud to be working with GeR and presenting their Vet Tech range of veterinary X-ray systems. There is a choice of power output of 12kW, 20kW and 30kW in the two presentations, Vet Tech and Vet Tech ClassicFor the characteristics of the Vet Tech Range, please click here.

 

The tables have been designed to incorporate all the requirements of veterinary X-ray practice. The 20kW and 30kW systems can be readily upgraded with a DR at a later date if required.

 

 

 

VET TECH CLASSIC X-RAY TABLE

 

 vet-tech_classic_image

 

1.5m table top

 

 

Software/Interface: 3 menus

 

 

Lower cost out of the 2 systems

 

 

200mA HF, 12kW

250mA HF, 20kW

300mA HF, 30kW

 

 

X-ray exposure by foot or handswitch

 

 

3kW electrical mains supply

 

 

 

 

 

vettechclassic_2 

 

 

High frequency technology

 

                 

 

vettech_3

 

  

4 way floating table

 

Cassette and grid trays

 

135kg weight load guaranteed

 

4 Rope ties attached to each corner of the table top 

    

  

 

 

 

 

 

 

  

 

Touch screen control interface

 

  

Solid mechanical brake system - foot activated 

 

 

Automatic radiographic parameter regulation in real time during the X-ray exposure 

 

 

Easy to install

 

 

 

An Intelligent and User Friendly Interface

The Vet-Tech system is controlled by a 15" touch-sensitive screen. (This can be fixed to the wall if required)

 

menu 

 

 

 

Automatic:

 

 

 

Manual:

Last case:

 

MENU SELECTION

 

All that the user needs to do is select the thickness of the body part or region. The radiographic parameters have been designed by Professor Paul Barthez (Dip ACVR, Dip ECVDI) and can be modified.

You select your own radiographic parameters

Gives access to the parameters of the last exposure that was performed.

.

 

The X-ray exposure sequence is controlled by electronics of the latest generation that provide with an optimised reliability:

 

 

- mA and kV regulation, in real time during the exposure sequence, ensures a constant and reproducible quality of images (this process is GeR exclusive and was granted an innovation trophy). This control replaces Automatic Exposure Control systems (AEC).

 

- A digital compensation mitigates electrical mains supply variations, which result in either over-exposed images or premature wearing of the X-ray tube.

 

- A reserve of energy, capacitors gives the advantages of the high frequency technology and significant reduction of the exposure time. The system needs a simple electrical supply line; 230V and 30Amps.

 

 

 

Vet Tech Classic

200mA HF

Vet Tech Classic

250mA HF 

Vet Tech Classic

300mA HF 

Power  12kW  20kW  30kW 
Rx Tube  Fixed anode  Rotating anode  Rotating anode 
Filament  3mm  1,3mm  0,6 / 1,3mm
Electrical mains supply line 230V 20A (3kW) 230V 20A (3kW) 230V 20A (3kW)
Maximum tube current  200mA  300mA  300mA 
mA range and increments  25 to 200, incr.25  25 to 300, incr.25 25 to 300, incr.25 
 kV range and increments 40 to 120, incr.1 40 to 120, incr.1  40 to 120, incr.1 
Focal distance  1 metre  1 metre  1 metre 
Automatic programme  805 combinations  805 combinations  805 combinations 
Dimensions (W x L x H) mm 85 x 1500 x 2010 85 x 1500 x 2010  85 x 1500 x 2010 
Total table pannel travel (W)  160mm  160mm  160mm 
Total table pannel travel (L)  650mm  650mm  650mm 

 

 

 

 Optional Extras

                                                                                                                                          

Swivelling Monobloc

 

 

The 'monobloc' is the part of the system at the top of the column and that contains the X-ray tube. The primary X-ray field can be swivelled upto 45deg to the right or to the left and enables to take radiographs of specific incidences such sinusitis for example. The 'zero' or rest position is marked by a notch. A handle is added to the monobloc to ease the swivelling.

 

  

  

   

 

swivelling_monobloc

 

Regulatory 

 

Vet-Tech X-ray systems are CE:

 

CEI 60601 certificate - electrical and mechanical safety standards, delivered parameters vs requested parameters challenged, X-ray emission leakages measured.

 

CEI 60601-1-2 certificate - Electro Magnetic Compatibility

 

NFC 74-100 certificate - Electrical design standard - French certificate demanded by ASN body (Nuclear Safety)

 

CE certificates - For all critical components supplliers: X-ray tube, collimators, tables, touch screen etc...

 

 

 

 